Cardiovascular Journal of Africa

Clinical outcomes and haemodynamic evolution following Perceval sutureless aortic valve implantation in high-risk aortic stenosis patients

Emced Khalil
Abstract
Background: Sutureless aortic valve replacement (AVR) has been recognised as a potential option in the management of high-risk patients, characterised by reduced procedural times and satisfactory haemodynamic results. However, mid-term results of valve-related outcomes are scarce. This study aimed to investigate clinical, echocardiographic, and valve-related outcomes of high-risk patients undergoing Perceval sutureless AVR.
Methods: The current retrospective, single-centre study included 50 consecutive high-risk patients who had isolated Perceval sutureless AVR. The time period was between January 2023 and December 2024. The primary endpoint was one-year valve-related survival. The secondary endpoints included echocardiographic performance, paravalvular leakage (PVL), patient-prosthesis mismatch (PPM), and the need for pacemaker implantation. Transthoracic echocardiography was performed at discharge and follow-up.
Results: Complete echocardiographic follow-up at 12 months was available for 44 patients (88%). The transvalvular gradient significantly decreased from 46.8 ± 11.2 to 12.4 ± 3.6 at discharge and remained stable at 12 months (12.1 ± 3.5; p < 0.001). The indexed effective orifice area increased from 0.58 ± 0.09 to 1.10 ± 0.16 cm²/m² at 12 months. No case of severe patient-prosthesis mismatch (PPM) was noted, but moderate PPM occurred in 12%. PVL was trivial or mild in all patients. Permanent pacemaker implantation was necessary in 20%, all within the index hospitalisation period, without any recovery of native conduction at follow-up. Valve-related survival at 12 months was 94%, with death from non-valve-related causes.
Conclusion: Sutureless Perceval aortic valve implantation has been shown to provide excellent clinical and haemodynamic results at midterm follow-up in high-risk patients with low rates of valve-related complications, PVL, and patient-prosthesis mismatch.
Keywords: Perceval, sutureless AVR, high-risk, haemodynamics, echocardiography, aortic stenosis
Submitted: January 15, 2026; Accepted: March 24, 2026; Published: July 3, 2026
Cardiovasc J Afr 2025; 37: 269-274
Volume 37, Issue 3
DOI Citation Reference: dx.doi.org/10.5830/CVJA-2026-020
Department of Cardiovascular Surgery, Trabzon Ahi Evren Cardiothoracic Surgery Training and Research Hospital, Trabzon, Türkiye
Emced Khalil

You need to be logged in to view and download the full text PDF version. Register for a free account?