Objectives:
This study evaluated routine chest X-ray necessity following ultrasound-guided totally implantable venous access port (TIVAP) placement via internal jugular vein.
Materials and methods: We retrospectively analysed 97 adults who underwent ultrasound-guided TIVAP placement at a tertiary cardiovascular surgery clinic in Eastern Turkey (December 2023–December 2024). Intraoperative port functionality (blood aspiration/fluid infusion) and post-procedural chest X-ray findings were assessed. Catheter positions were categorised as optimal, suboptimal, or malpositioned.
Results: Among 97 patients (56.7% male; mean age 57.4 ± 15.0 years), pneumothorax occurred in one patient (1.0%), requiring intervention. Nineteen patients (19.6%) had suboptimal/malpositioned catheter tips but required no corrective action as port functionality remained intact. Radiographic findings prompted intervention in only one patient (1.0%).
Conclusions: Routine post-procedural chest X-ray identified catheter tip malpositioning in a subset of patients; however, these findings did not alter clinical management in the absence of port dysfunction. Selective imaging in patients with failed port functionality may safely reduce unnecessary radiation exposure and healthcare costs without compromising outcomes.
Materials and methods: We retrospectively analysed 97 adults who underwent ultrasound-guided TIVAP placement at a tertiary cardiovascular surgery clinic in Eastern Turkey (December 2023–December 2024). Intraoperative port functionality (blood aspiration/fluid infusion) and post-procedural chest X-ray findings were assessed. Catheter positions were categorised as optimal, suboptimal, or malpositioned.
Results: Among 97 patients (56.7% male; mean age 57.4 ± 15.0 years), pneumothorax occurred in one patient (1.0%), requiring intervention. Nineteen patients (19.6%) had suboptimal/malpositioned catheter tips but required no corrective action as port functionality remained intact. Radiographic findings prompted intervention in only one patient (1.0%).
Conclusions: Routine post-procedural chest X-ray identified catheter tip malpositioning in a subset of patients; however, these findings did not alter clinical management in the absence of port dysfunction. Selective imaging in patients with failed port functionality may safely reduce unnecessary radiation exposure and healthcare costs without compromising outcomes.
Keywords:
totally implantable venous access port, ultrasound-guided, internal jugular vein, chest X-ray, pneumothorax
Submitted: October 26, 2025;
Accepted: May 18, 2026;
Published: August 28, 2026
Cardiovasc J Afr 2025; 37: 358-364
Volume 37, Issue 3
Cardiovasc J Afr 2025; 37: 358-364
Volume 37, Issue 3
DOI Citation Reference: dx.doi.org/10.5830/CVJA-2026-027